現xian在zai市shi麵mian上shang空kong調tiao製zhi冷leng劑ji加jia注zhu,除chu了le少shao量liang的de修xiu理li廠chang或huo快kuai修xiu快kuai保bao店dian,在zai使shi用yong空kong調tiao冷leng媒mei回hui收shou加jia注zhu一yi體ti機ji,大da部bu分fen還hai是shi使shi用yong的de簡jian式shi的de冷leng媒mei加jia注zhu工gong具ju。而er且qie很hen多duo人ren在zai使shi用yong簡jian式shi冷leng媒mei加jia注zhu工gong具ju時shi都dou使shi冷leng媒mei瓶ping口kou向xiang下xia,由you低di壓ya端duan加jia注zhu冷leng媒mei,那na這zhe樣yang加jia注zhu冷leng媒mei正zheng不bu正zheng確que?
在此之前我們要先了解空調係統的基本組成和運行原理:
空調係統組成:
壓縮機、冷凝器、膨脹閥、儲液幹燥罐、蒸發箱、散熱風扇、傳感器、管路等組成。
運行原理:
壓(ya)縮(suo)機(ji)吸(xi)入(ru)低(di)壓(ya)低(di)溫(wen)的(de)氣(qi)態(tai)製(zhi)冷(leng)劑(ji)進(jin)行(xing)壓(ya)縮(suo)做(zuo)功(gong),從(cong)壓(ya)縮(suo)機(ji)排(pai)出(chu)的(de)製(zhi)冷(leng)劑(ji)流(liu)入(ru)冷(leng)凝(ning)器(qi)此(ci)時(shi)的(de)製(zhi)冷(leng)劑(ji)為(wei)高(gao)溫(wen)高(gao)壓(ya)的(de)氣(qi)態(tai),製(zhi)冷(leng)劑(ji)在(zai)冷(leng)凝(ning)器(qi)內(nei)通(tong)過(guo)散(san)熱(re)風(feng)扇(shan)進(jin)行(xing)散(san)熱(re)。

高gao溫wen高gao壓ya的de氣qi態tai製zhi冷leng劑ji變bian為wei中zhong溫wen高gao壓ya的de液ye態tai製zhi冷leng劑ji流liu出chu冷leng凝ning器qi,並bing流liu經jing儲chu液ye幹gan燥zao罐guan進jin行xing過guo濾lv到dao達da膨peng脹zhang閥fa,中zhong溫wen高gao壓ya的de液ye態tai製zhi冷leng劑ji經jing過guo膨peng脹zhang閥fa進jin行xing截jie流liu流liu入ru蒸zheng發fa箱xiang。
流入的少量製冷劑此時是低壓液體狀態並在蒸發箱內快速蒸發變為低溫低壓的氣態製冷劑,再被壓縮機吸入進行壓縮做功進行反複循環
通過上述空調係統工作原理可以看出:
壓縮機工作吸入與排出的都為氣態製冷劑,那我們使用簡式冷媒加注工具時,使冷媒瓶口向下從低壓口加注液態製冷劑顯然是錯誤的。
所以正確的冷媒加注方法應該是:
1.冷媒添加:啟動車輛,開啟空調製冷,使冷媒瓶口向上,打開低壓端閥門進行加注,注意加注量
2.重新加注冷媒:在抽完真空狀態下,冷媒瓶口向下打開高壓端閥門加注液態製冷劑,加注不進後,關閉閥門。
冷(leng)媒(mei)瓶(ping)口(kou)向(xiang)上(shang)打(da)開(kai)低(di)壓(ya)端(duan)閥(fa)門(men)加(jia)注(zhu)氣(qi)態(tai)製(zhi)冷(leng)劑(ji),加(jia)注(zhu)不(bu)進(jin)後(hou),關(guan)閉(bi)閥(fa)門(men),啟(qi)動(dong)車(che)輛(liang),開(kai)啟(qi)空(kong)調(tiao)製(zhi)冷(leng),打(da)開(kai)低(di)壓(ya)端(duan)閥(fa)門(men)冷(leng)媒(mei)瓶(ping)口(kou)向(xiang)上(shang)繼(ji)續(xu)加(jia)注(zhu)氣(qi)態(tai)製(zhi)冷(leng)劑(ji),注(zhu)意(yi)加(jia)注(zhu)量(liang)
廣州中冷認為雖然加注氣態製冷劑比較緩慢,但是這是確保不會損傷壓縮機和空調係統的正確加注方法。
一個中國。一家冷凍化工公司。一站解決。